TECHNICAL SPECIFICATIONS

DIMENSIONS:

Containers are produced as 1. type in 2400x6000x2600 mm as 2. type 3000x7000x2600 mm

EXTERIOR WALLS:

0.70 mm thick trapezoidal Ral 9002 electrostatic powder coated sheet metal is used on outer surfaces of exterior wall. 8 mm white chipboard laminated on both sides are used inner surface of exterior wall. 40 mm mineral wool (40 kg/m³) is placed between the exterior walls.

INTERIOR WALLS:

8 mm white chipboard laminated on both sides are used on both surfaces. 40 mm mineral wool (40 kg/m³) is placed between the interior walls. 8 mm cemented chipboards are used in WC and shower volumes.

CONTAINER ROOF:

The roof is coated with 0.60 mm thick galvanized trapezoidal sectioned sheet metal in 27/200 form. Rain waters are discharged by secret gutter placed on corners.

BUILDING ROOF:

The roof is coated with 0.50 mm thick galvanized trapezoidal sectioned sheet metal in 27/200 form.Roof Truss is made of galvanized steel by Roolforming machine.

CEILING:

Ceiling is covered with a 8 mm white chipboard laminated on both sides. Then coated with a 80 mm thick (14 kg/m³) glass wool.

CONTAINER FLOOR:

0.50 mm thick trapezoidal galvanized sheet metal are screwed on steel carcass and covered 18 mm chipboard and then coated with 2.5 mm vinyl flor covering. WC – shower are coated with 16 mm cemented chipboard and ceramics

DOORS:

The exterior doors are made of 0.70 mm thick Ral 9002 electrostatic powder coated sheet metal. 50 mm thick extrude polystyrene hard foam is placed in to doors. Inner doors are wood pressed doors.

WINDOWS:

Windows are made of PVC profiles and fitted with double glazed (4+9+4) mm and fixed flyswatter. As standart 80x110 windows are used in normal areas. 60x40 windows are used in WC-shower volumes.

ELECTRICAL INSTALLATION:

There are electrical installation that can bear a power of 2000W and 220V , air conditioner electrical installation is done in respect to setting plan. 2*40 fluorescent is used in normal areas, round globe is used in wet volumes and exterior globe is used above exterior door. All used materials meet T.S.E. Turkish standart.There are electrical installation that can bear a power of 2000W and 220V , air conditioner electrical installation is done in respect to setting plan. 2*40 fluorescent is used in normal areas, round globe is used in wet volumes and exterior globe is used above exterior door. All used materials meet T.S.E. Turkish standart.

SANITARY INSTALLATION:

All clean water pipes are used by pprc pipes, waste water pipes are used by pvc pipes. WC , washbasin , kitchen basin are placed in respect to setting plan. All used materials meet T.S.E. Turkish standart.

PAINT:

The surface of exterior steel frame are painted epoxy primer and later industrial paint.